Lattner 24AF

SteamEase Series Electric Steam Bath Boiler, 24KW

Model
24AF
SKU
24-BF-S

Lattner 24AF, Electric Steam Bath Boiler, is engineered to power rooms up to 960 cubic feet (CF). Includes digital operating control package for single or dual room application (select below). The Lattner Steamease AF series includes 1 steam head per room.

See Shipping Tab

Your Price
$8,065.00

Designed for the most demanding commercial steam room environments, this SteamEase Series boiler system operates under pressure and is capable of steaming rooms (1-2) up to a total of 960 cubic feet. Complete with incoloy heating elements, magnetic contactors, NEMA-1 panel with boiler and feedwater ON/OFF switch, lamps, McDonnell Miller primary water level control, auxiliary low water cut-off w/manual reset, operating pressure control, high limit w/manual reset, all internal ungrounded circuits subdivided and fused between contactors and source terminals, ASME safety valve, blowdown valve, feedwater stop and check valves, and water gauge set with ball checks and glass protector.

Lattner boilers employ a minimum 13" diameter X 23-1/4" long vessel with an unusual 284 square inch steam release area to ensure the production of dry steam without water carry-over. This large reservoir holds an impressive 13-gallons of water during operation and enables the use of superior low watt density immersion heaters. Additionally, the horizontal type boiler shell provides for an extremely large sediment collection area.

Also available in 480V/3PH, 240V/3PH and 240V/1PH operation. Consider the highly recommended 1674-B Automatic Blowdown System for automated on/off and drain capabilities.

NOTE: Additional Freight Charges May Apply.

  • Industrial grade incoloy heating elements
  • Fully insulated shell with metal jacket
  • Automatic operating controls
  • ASME low-pressure operation compliance
  • National Board registered vessel
  • Room hi-limit pressure control
  • Operates with digital room temperature controller
  • Operating, electronic hi-limit and ASME safety valve pressure control system
  • Safety valve
  • Blowdown valves for boiler and level control
  • On/off switch and terminals for connection of feed water equipment
  • UL listed and built to ASME code
  • 24AF, 24BF, 24CF, or 24F Steam Boiler
  • Digital room temperature controller, single or dual
  • One (1) waterproof sensor with shield per room
  • One (1) factory-wired steam solenoid valve assembly per room
  • One (1) steam head per room
Swipe horizontally to reveal full table content.
Model 24AF
Minimum Adjusted Cubic Feet 720
Maximum Adjusted Cubic Feet 960
Kilowatt Rating 24 KW
Shipping Weight 445 lbs
AC Voltage 208V AC
Phase 3 Phase
Nominal Amperage 66.7 Amps
Water Supply Connection 3/4" NPT
Generator Steam Line Connection 1" NPT
Length 38"
Width 27"
Height 29"

 

The weight or packaging of this product requires delivery by special appointment, and on a wooden pallet. 

The driver is responsible for curbside delivery “only” and will lower the items to ground level. 

Prior to shipping this product, we contact customers to share shipment details and discuss any extenuating delivery circumstances that may complicate or cause additional delivery expenses. 

Our goal is to ensure your project's success.

.